Više detalja možete provjeriti ovdje.
| ORDER INFORMATION | |
|---|---|
| EAN Number | 5702663062214 |
| SHIELDING | |
| Shielding @ 30-300 MHz | ≥ 95.0 dB |
| Shielding @ 300-470 MHz | ≥ 90.0 dB |
| Shielding @ 470-1000 MHz | ≥ 85.0 dB |
| Shielding @ 1000…2400 MHz | ≥ 65.0 dB |
| CHARACTERISTICS | |
| Type | GDA |
| Outlet Type | Loop through |
| FREQUENCY | |
| Frequency Range IN-OUT | 5…2150 (2400) MHz |
| Frequency Range FM | 5…118 MHz |
| Frequency Range TV | 5…862 MHz |
| Frequency Range SAT | 950…2150 (2400) MHz |
| LOSS | |
| Through Loss IN-OUT | 1.4±0.8 dB |
| Through Loss IN-OUT @SAT | 1.8±1.0 dB |
| Through Loss IN-FM | 17.0 ±1.0 dB |
| Through Loss IN-TV | 12.5 ±1 dB |
| Through Loss IN-SAT | 12.0 ±1.5 dB |
| ISOLATION | |
| Isolation OUT-FM | 35.0 dB |
| Isolation OUT-TV | 28.0 dB |
| Isolation OUT-SAT | 18.0 dB |
| Isolation FM-SAT | 35.0 dB |
| Isolation TV-SAT | 20.0 dB |
| Isolation TV-FM | 25.0 dB |
| RETURN LOSS | |
| Return Loss – Out 5-40 MHz | 18.0 dB @40MHz -1.5dB/Oct. dB |
| Return Loss IN | 16.0 (@40MHz -1.5dB/Oct.) dB |
| Return Loss OUT | 15.0 dB |
| Return Loss FM | 10.0 dB |
| Return Loss SAT | 10.0 dB |
| Return Loss TV | 12.0 dB |
| ELECTRICAL | |
| Impedance | 75 Ω |
| OPERATIONAL | |
| Certification | EN 50083-1, EN 50083-2, EN 50083-4 |
| Screening Efficiency | EN50083-2 (Class A+10dB) |
| DC Passthrough IN-OUT | Yes (max. 25VDC / 0.5A) |
| DC Passthrough TV | NO – DC blocked at inner conductor |
| DC Passthrough FM | NO – DC blocked at inner conductor |
| DC Passthrough SAT | Yes (max. 25VDC / 0.5A directed) |
| MTBF (mean time between failures) | >1.000.000 hours |
| Temperature – operating | -25…55 °C |
| Temperature – storage | -25…55 °C |
| Temperature – shipping | -40…70 °C |
| CONNECTORS | |
| Connector IN-OUT | Spring Clamp Termination |
| Connector FM | IEC-female |
| Connector TV | IEC-male |
| Connector SAT | F-female |
| Adaptable Cable Diameters – Inner Conductor | 0,58…1.15 mm |
| Adaptable Cable Diameters – F-female | 0.6…1.13 mm |
| Adaptable Cable Diameters – Outer Conductor | 3.7…5.8 mm |
| Adaptable Cable Diameters- Jacket | 4.5…7.2 mm |
| MECHANICAL | |
| Tensile Strength – Inner Conductor 1 (Ø) | > 25 @ 0.75mm N/mm2 |
| Tensile Strength – Inner Conductor 2 (Ø) | > 50 @ 1.13mm N/mm2 |
| Main material | Zinc diecast |
| Dimensions product (H x D x W) | 70.6 x 70.6 x 21.9 mm |
| Packaging Height | 0,400 m |
| Packaging Width | 0,700 m |
| Packaging Depth | 0,700 m |
| Packaging Volume | 0,196 m3 |
| Net Weight | 0,103 kg |
| Tara Weight | 0,008 kg |
| Total Weight | 0,111 kg |